Equipment fails slowly. The supply temp drifts 2°F. The chilled water valve hunts. The economizer leaks. Signal FDD catches these patterns weeks before alarms surface or tenants complain.

Rule + MLHVAC FDDControls DriftEnergy Waste
02 / Detections

What Signal catches.

Six fault families across HVAC, controls, and metering systems.

HVAC

Equipment faults.

Failed sensors, stuck dampers, hunting valves, simultaneous heating and cooling, low delta-T syndrome, degraded heat exchangers.

40+
detection rules baked in
Controls

Sequence drift.

Sequences that no longer match the design intent. Manual overrides left active. Schedule violations. Setpoints overridden at the device level.

Energy

Energy anomalies.

Off-hours consumption, schedule mismatches, weekend baseline drift. Tied to building schedules and weather.

ML

Pattern detection.

Self-learning baselines flag deviations the rule library missed. Catches degradation patterns weeks ahead of alarm thresholds.

03 / In Practice

Diagnostic check error rates.

Live FDD scoring across every check across every asset. Color-coded by severity, ranked by impact, drilled into by trend. The fault is not just "AHU-3 is bad." The fault is "FDD-1842: AHU-3 economizer leakage causing 14% supply-air over-cooling."

A·IQ screenshot
04 / Under the Hood

Real configuration.

How this looks in your stack.

Rule
fdd-1842-economizer-leak.yaml.
id: FDD-1842
name: "Economizer leak detection"
applies_to: ["ahu", "rtu"]
when:
  oat: "> 75 °F"
  economizer_cmd: "closed"
  supply_temp_delta: "> 4 °F below setpoint"
duration: "> 30 min"
severity: 3
Output
fault payload.
{
  "fdd_code": "FDD-1842",
  "asset": "@b3.ahu-3",
  "first_seen": "2026-05-09T04:13Z",
  "impact_kw": 14.2,
  "severity": 3,
  "recommend_wo": true,
  "runbook": "economizer-actuator.pdf"
}
05 / Security

Your data. Your infrastructure.

On-premise by default. Cloud-deployable when required. Your facility data never leaves your network.

TLS everywhere, secrets in vault, row-level security on every query. Containerized and isolated so one service going down never takes the rest with it.

A·IQ is built by Arcis FM, a Service-Disabled Veteran-Owned Small Business (SDVOSB). Set-aside eligible for federal contracts. CAGE 14DG6 · UEI Z95MQL2KEYG3.

TLS Everywhere
Service-to-service · client-to-server · API-to-database
On-Premise
Inside your firewall · zero cloud subscription required
Air-Gap Capable
Operates without any internet connectivity
SDVOSB Certified
CAGE 14DG6 · UEI Z95MQL2KEYG3 · set-aside eligible
Row-Level Security
Multi-tenant isolation at the database level
NIST 800-171
OT network segmentation · firmware governance
06 / Reference

Common Questions.

Engineer and operator questions on this capability.

01

What faults does Signal detect?

40+ baked-in rules across HVAC equipment, controls sequences, and energy patterns plus ML-driven anomaly detection that learns your building's baseline.

02

Do we have to write the rules?

No. The default library covers most equipment types out of the box. Custom rules for unusual sequences or proprietary equipment can be added.

03

How does FDD relate to alarms?

Alarms are reactive they fire when a threshold is crossed. FDD is proactive it identifies sequences that will cause an alarm if not addressed.

04

Can FDD trigger work orders?

Yes. With Nexus, every detected fault can auto-create a work order with the runbook, parts list, and assigned technician attached.

07 / Related

Pair with these.

FDD finds the fault. RCA finds the cause. Work orders close the loop.

Catch the fault. Then the next 39.

Send us 30 days of BAS history. We will run our FDD library against it and show you the faults already happening in your building right now.

Federal & State Certifications
SBA Certified Service-Disabled Veteran-Owned Small Business California Disabled Veteran Business Enterprise California Certified Small Business